The caliper is the most used measuring instrument in the shop: one tool measures outside and inside diameters, slot widths, depths and steps. This page covers the parts of a caliper, the main types, step-by-step vernier reading examples and how to avoid measuring errors.
Parts of a vernier caliper

- Beam and main scale: the millimetre graduations are on the fixed scale on the beam.
- Slider and vernier scale: the vernier on the slider that carries the moving jaw reads fractions of a millimetre.
- Outside jaws: measure outside diameters and thickness.
- Inside jaws: measure bores and slots.
- Depth rod: moves out of the end of the beam with the slider and measures depth.
- Locking screw: holds the reading on the instrument.
- Step faces: the ends of the beam and slider are used to measure steps.
According to DIN 862, vernier calipers are made with 1/10, 1/20 and 1/50 mm resolution in metric and 1/64″, 1/128″ and 1/1000″ in inch.
Caliper types
Dial caliper

It is used exactly like a vernier caliper; the difference is a dial instead of the vernier on the slider. Metric dial calipers usually read 0.02 mm or 0.05 mm. A dial is faster and less tiring to read than a vernier.
Digital caliper

Mechanically it is the same as a vernier caliper; the reading appears on a battery-powered display. It reads 0.01 mm in metric and 0.001″ in inch. It usually has on/off, zero and mm/inch buttons, and some models have a data output to send readings to a computer. On absolute (ABS) digital calipers the origin must be set again after a battery change.
Depth caliper

It measures the depth of steps, grooves and blind holes. The wide base sits on the top face of the part and the scale is lowered. Resolutions are the same as for standard calipers.
Special-purpose calipers

Narrow spaces such as circlip grooves, steps inside bores and surfaces that standard jaws cannot reach need calipers with special jaws. There is also a gear tooth caliper for measuring gears.
Measuring correctly with a caliper


- Outside measurement: hold the part close to the jaw roots. Measuring at the jaw tips magnifies the error from slider play.
- Inside measurement: insert the jaws as deep as possible and repeat a few times. Take the largest reading for a bore and the smallest reading for a slot width.
- Depth measurement: keep the beam square (90°) to the reference face and take the smallest reading.
- Measuring force: too much force on the slider tilts the moving jaw. For example, if the jaw tilt is 0.01 mm over 50 mm, the error at a jaw depth of 40 mm is (40/50) × 0.01 = 0.008 mm.
How do you read a vernier caliper?
Reading takes three steps:
- Read the whole millimetre that the vernier zero line has passed on the main scale.
- Find the vernier line that lines up exactly with a main-scale line and multiply its number by the caliper resolution.
- Add the two values.
Reading a 1/10 (0.1 mm) caliper

On the vernier, 9 mm of the main scale is divided into 10 equal parts. Vernier lines are 0.9 mm apart, so the difference from the main scale is 1 − 0.9 = 0.1 mm.

- The vernier zero has passed 8 mm on the main scale.
- The coinciding vernier line is line 3: 3 × 0.1 = 0.3 mm.
- Reading: 8 + 0.3 = 8.3 mm.
Reading a 1/20 (0.05 mm) caliper

On the vernier, 19 mm is divided into 20 equal parts. Vernier spacing is 0.95 mm and the difference is 1 − 0.95 = 0.05 mm. This is the most common vernier caliper in workshops.

- The vernier zero has passed 10 mm.
- The coinciding vernier line is line 9: 9 × 0.05 = 0.45 mm.
- Reading: 10 + 0.45 = 10.45 mm.
Reading a 1/50 (0.02 mm) caliper

On the vernier, 49 mm is divided into 50 equal parts. Vernier spacing is 0.98 mm and the difference is 0.02 mm. It is preferred for more precise work.

- The vernier zero has passed 12 mm.
- The coinciding vernier line is line 17: 17 × 0.02 = 0.34 mm.
- Reading: 12 + 0.34 = 12.34 mm.
Reading an inch caliper (1/128″)

On the main scale one inch is divided into 16 equal parts, so each main-scale division is 1/16″ = 8/128″. Each vernier line adds 1/128″.

- Whole inches: 2″.
- After 2″ the vernier zero has passed 10 main-scale lines: 10 × 8/128 = 80/128″.
- The coinciding vernier line is line 3: 3/128″.
- Reading: 2 + 80/128 + 3/128 = 2 83/128″.
Reading a dial caliper

- Main-scale value passed by the slider: 70 mm.
- The dial pointer is on line 38: 38 × 0.02 = 0.76 mm.
- Reading: 70 + 0.76 = 70.76 mm.
Caliper care and storage
- Before use, clean the measuring faces by closing the jaws on a clean piece of paper and pulling it out; then close the jaws and check zero.
- Wipe the sliding faces with a dry, soft cloth. After use, remove water and oil and apply a thin film of anti-corrosion oil to the moving parts.
- The jaws are sharp; handle them carefully. Do not drop the caliper or expose it to electric current.
- Store away from sunlight, extreme temperatures and humidity. Do not store with the jaws fully closed. Remove the battery from a digital caliper that will not be used for a long time (for example more than three months).
Common caliper mistakes
- Picking the coinciding vernier line while looking from the side (parallax error).
- Measuring at the jaw tips or squeezing the slider too hard.
- Measuring a hot part.
- Not taking the largest reading for a bore and the smallest for a slot.
- Relying on a caliper for tight tolerances; measure those with a micrometer: micrometer types and reading.
For the other instruments and how to choose the right one: measuring instruments guide.
Disclaimer
The information on this page is for general training purposes. Use and care requirements for measuring instruments vary by manufacturer and model; your instrument’s manual and your company’s quality procedures always take priority. An instrument that is out of calibration or damaged gives wrong results. Mentor CNC cannot be held responsible for damage, scrap or injury arising from the use of this information.