CNC Coolant (Soluble Oil): Concentration, Mixing and Maintenance on CNC Machines

15 November 2026

Mentor CNC Editorial Team

On a CNC machine, the fluid that keeps the insert and the workpiece from overheating is the water-miscible coolant, usually called soluble oil or emulsion; manuals also call it cutting fluid or metalworking fluid. Mixed at the right ratio and checked regularly, it runs for months without trouble. Left alone, it starts to smell, foams, rusts parts and machine, and irritates the operator’s skin. This article explains what the coolant does, how to mix and measure it, and how to solve the most common problems at the machine.

Coolant (soluble oil) tank and pump under the chip conveyor of a CNC lathe
On a CNC lathe the coolant sits in a tank under the chip conveyor; the pump sends it through a filter to the hoses on the spindle side and the turret.

What Is Soluble Oil Coolant and What Does It Do?

Soluble oil coolant is oil dispersed in water as very small droplets. It is sold as a concentrate and mixed with water before use. Three components work together in the mix:

  • Water is the best coolant; it carries heat away from the cutting zone.
  • Oil reduces friction; it forms a lubricating film between tool and chip.
  • Emulsifier keeps oil and water from separating.

On a CNC machine the coolant has four jobs:

  1. It cools the cutting tool and the workpiece and reduces thermal size drift.
  2. It reduces friction between tool and chip, extending tool life and improving surface finish.
  3. It flushes chips out of the cutting zone and out of holes.
  4. It gives the machined part and the inside of the machine short-term rust protection.

Compared with straight oil it is far less of a fire risk, costs less and does not leave an oily film on the part, which is why it is the most common coolant on CNC lathes and machining centers. In the program, coolant is switched on with M08 and off with M09; see the FANUC G and M code list for the other codes.

What Types of Metalworking Fluid Are There?

TypeOil content of the concentrateAppearance when mixedTypical use
Straight (neat) cutting oil, not mixed with water100%Yellow, oilyHeavy threading, broaching and difficult hole work where lubrication matters more than cooling
Soluble oil60–90%Milky whiteGeneral turning, milling and drilling where lubricity matters
Semi-synthetic2–30%TranslucentJobs that need both cooling and lubricity
Full synthetic0%ClearMainly grinding; more resistant to bacteria

This article covers the water-miscible fluids: soluble oil and its semi-synthetic and synthetic relatives. Straight cutting oil is not mixed with water and is maintained differently.

What Should the Coolant Concentration Be?

Important: The correct mix ratio is the one recommended by the manufacturer of the product you use. It is given on the product data sheet or the container; if not, ask the manufacturer or supplier. The values below are typical ranges given by Mentor CNC for general information and do not replace the manufacturer’s recommendation.

Water-miscible coolants are usually run at 2% to 10%. Some special operations fall outside this range. Manufacturers usually give a range by operation type: the lower end for light work, the upper end for demanding work such as threading, tapping and deep-hole drilling.

  • Concentration too low: parts and machine rust, lubrication is weak, tools wear faster, bacteria grow easily.
  • Concentration too high: foaming, sticky residue and skin irritation, and the concentrate is wasted.

How Do You Mix Coolant?

  1. Know the tank volume. You need the volume to calculate how much concentrate to use. For example, if the manufacturer recommends 5%, a 200-litre tank needs 10 litres of concentrate and 190 litres of water.
  2. Clean the tank. Fresh emulsion poured into a dirty sump is reinfected by the old bacteria within days.
  3. Water first, then oil. Add the concentrate slowly into the water while stirring. Pouring water onto the concentrate gives an unstable emulsion that separates quickly.
  4. Mix in a separate container. Where possible, prepare the emulsion in a clean container or with a mixer and then transfer it to the sump. Mixing inside the machine sump does not give a uniform emulsion.
  5. Measure the concentration of the new mix with a refractometer.

What Water Should You Use?

About 95% of the emulsion is water, so water quality directly affects the result. Typical values given by coolant manufacturers:

PropertyTypical valueIf out of range
Total hardnessAbout 5–20 °dH (≈ 90–360 ppm CaCO₃)Very soft water foams; very hard water splits the emulsion and causes rust
ChlorideLow; manufacturers usually set an upper limit of 25–50 mg/LHigher chloride means higher corrosion risk
Microbiological qualityClean, preferably drinking-water qualityContaminated water brings bacteria into the sump from day one

Do not use well water, cistern water or uncontrolled treated water without testing it. Exact limits depend on the product; check its data sheet.

How Do You Measure Coolant Concentration With a Refractometer?

A refractometer is a small optical instrument that shows the concentration in a few seconds.

  1. Put a few drops of clean water on the prism and set the scale to zero.
  2. Dry the prism and put a few drops of coolant from the sump on it.
  3. Hold it towards the light and read the value where the light–dark boundary crosses the scale.
  4. Multiply the reading by the product’s refractometer factor.

% Concentration = Refractometer reading × Refractometer factor

Example: the scale reads 4 and the product factor is 1.5, so the concentration is 6%. The factor differs from product to product and is given on the data sheet. Always compare the result with the concentration recommended by the manufacturer.

A refractometer shows concentration only. Bacteria, a falling pH or tramp oil on the surface do not show up in this reading; they need separate checks.

Which Coolant Checks Should Be Done, and How Often?

CheckHowHow oftenTypical value / warning sign
Sump levelVisualAt the start of every shiftA low level makes the pump suck air and foam
ConcentrationRefractometerDaily; every shift on busy machinesThe manufacturer’s recommended ratio
pHpH strips or pH meterDaily8.5–9.5 for most products; below 8.5 signals bacteria and rust risk, above 9.5 is a skin risk
Bacteria and fungiDip-slideWeekly or when in doubtAbove 1 million (10⁶) per millilitre needs action
TemperatureThermometerIn hot periodsBacteria grow fast above 25 °C
Appearance and smellVisual and smellDailyColour change, oil on the surface, bad smell

Write down every reading and every top-up in a log. Coolant does not go bad in a day but over weeks; a log shows the trend before it becomes a problem. The other checks done at the start of a shift are in our daily operator checks on a CNC machining center article.

How Should You Top Up the Coolant?

The sump loses fluid in two ways. In a warm sump, water evaporates and the concentration rises. Chips, on the other hand, carry oil out of the sump and the concentration drops. That is why the sump is never topped up with water alone or with concentrate alone. Measure first, then add emulsion premixed in a separate container at the manufacturer’s ratio. If the concentration has risen, add a leaner mix; if it has dropped, a richer one. Measure again after topping up.

Why Does Coolant Smell, Foam or Split?

SymptomLikely causeWhat to do
Bad smell (“rotten eggs” or “locker room”), grey-black colourBacterial growth; pH usually dropsSkim off tramp oil, correct concentration and pH, keep the fluid circulating. If the bacteria count is high, add the biocide recommended by the manufacturer at the stated dose. If it does not recover, clean the sump and replace the fluid.
Foam in the sump and on the toolVery soft water, high concentration, low sump level (pump sucks air), high-pressure nozzles, cleaner contaminationMeasure concentration, top up the level, check water hardness. Use the manufacturer’s defoamer if needed.
Split emulsion: cream or oil layer on top, water belowHard water, reverse mixing (water poured onto oil), bacteria, too much tramp oilCheck water hardness and mixing order. A split emulsion usually cannot be saved and is replaced.
Rust on parts and machineLow concentration, falling pH, high chloride in the waterMeasure and correct concentration and pH, check the water values.
Yellow-brown colour, oil layer on the surfaceWay oil or hydraulic oil leakage (tramp oil)Skim it off and find the source of the leak (next section).
Redness and itching on the operator’s handsHigh concentration, pH above 9.5, contaminated emulsionMeasure concentration and pH, follow personal protection rules.

A spoiled soluble-oil emulsion often turns light blue or leaden grey and gives off a sharp smell. That means the bacteria are out of control. They multiply fastest in oxygen-starved, warm sumps.

What Happens When Way Oil Gets Into the Coolant?

On most CNC machines the oil sent to the ways and ball screws is not collected; it ends up in the coolant sump. Small hydraulic leaks go the same way. This oil is called tramp oil, and it is one of the main reasons coolant life is cut short.

Tramp oil is lighter than water and forms a layer on the sump surface. That layer cuts the fluid underneath off from air. In the oxygen-starved sump bacteria multiply quickly, pH drops, and the fluid starts to smell and to rust the inside of the machine.

A quick check: after the machine has stood for a while, push the oil layer aside with your hand or a cup. If the gap closes again within 5–8 seconds, there is too much tramp oil in the sump.

  • Remove surface oil regularly with a skimmer or absorbent pads.
  • If the way-oil level drops faster than usual, have the lubrication unit setting and possible leaks checked.
  • Choose a way oil that separates easily from coolant. We cover this in our way oil, hydraulic oil and grease article.

How Do You Protect Coolant When the Machine Stands Idle?

Over weekends and holidays the fluid standing in the sump runs out of oxygen and bacteria grow; that is where the Monday-morning smell comes from. If the machine will stand for more than two days, circulate the coolant for at least 1 hour every 48 hours. Skim off tramp oil before shutting down. Never throw food, cigarette ends or ash into the sump; they are food for bacteria.

When Should Coolant Be Changed, and How Is the Sump Cleaned?

There is no fixed coolant life; an emulsion kept at the right concentration, pH and appearance lasts a long time. Change it when the smell does not go away after correction, the emulsion has split, the pH keeps falling, or the bacteria count does not drop despite biocide. On heavily used machines, drain and clean the sump at least once a year.

  1. Before draining, with the old fluid still in the machine and running, add the manufacturer’s system cleaner at the stated ratio and run for the time given in the instructions. It loosens the bacterial film in pipes and channels you cannot reach.
  2. Drain the dirty fluid.
  3. Remove chips and sludge from the sump and check the filters and strainers.
  4. Flush the system with clean water and drain that water too.
  5. Mix the new emulsion water first, then oil, at the manufacturer’s ratio, and measure its concentration.

Used coolant is hazardous waste; it must not go down the drain and is handed over to a licensed waste contractor.

What Health Precautions Apply When Working With Coolant?

The most common health problem with coolant is irritation and eczema of the hands and forearms (contact dermatitis). Long contact with contaminated or over-concentrated emulsion increases the risk. The machine enclosure and mist collector reduce the oil mist the operator breathes during cutting.

  • At the start of the shift, apply a barrier cream suited to the fluid type to exposed skin; at the end, wash with lukewarm water and mild soap and moisturise.
  • Do not wash your hands in the coolant; do not clean them with solvent, thinner, detergent or swarf.
  • Do not use torn gloves or gloves that are dirty inside; do not wipe your hands with dirty rags.
  • Change work clothes soaked with coolant; do not carry oily rags in your pockets.
  • Keep the machine doors and guards working; make sure the mist collector filter is cleaned regularly.

You can ask the supplier for the product’s safety data sheet. If skin redness does not clear or breathing complaints appear, see the occupational physician.

Frequently Asked Questions

What should the coolant concentration be? The correct ratio is the one recommended by the manufacturer of your product; it is on the data sheet or the container. As general information, water-miscible coolants usually run at 2–10%, near the top of the manufacturer’s range for heavy work and near the bottom for light work.

Can you top up coolant with water only? No. Measure the concentration with a refractometer first, then add emulsion premixed at the manufacturer’s ratio. Water alone lowers the concentration and raises the risk of rust and bacteria.

Why does coolant smell? A bad smell means bacteria are growing. Tramp oil on the surface, low concentration, long idle periods and rubbish thrown into the sump all speed this up.

Why does coolant foam? Very soft water, high concentration, a low sump level and high-pressure nozzles are the most common causes.

Why does coolant split? Hard water, reverse mixing (water poured onto the concentrate), bacteria and too much tramp oil break the emulsion.

Safety Notice and Disclaimer

Coolant products work with different ratios, pH values and water specifications. The values in this article are general information; for every value, and above all the mix ratio, the recommendation of your product’s manufacturer, its data sheet and its safety data sheet take precedence. Use additives such as biocides and system cleaners only at the dose the manufacturer recommends. The information in this article is for educational purposes; Mentor CNC accepts no liability for direct or indirect damage arising from its use.

Mentor CNC logo

MENTOR CNC
CNC knowledge from the shop floor

Mentor CNC turns hands-on shop-floor experience in CNC turning, CNC milling, CNC controls, cutting tools and engineering calculations into clear, practical technical content.

Our goal is to help operators, students, engineers and shop owners reach accurate information faster and make safer, more efficient decisions in production.