A micrometer measures more precisely than a caliper and is used to check tight-tolerance diameters. It works on the screw-and-nut principle: one turn of the spindle advances it by the screw pitch, and the graduations on the thimble divide that movement into small steps. This page covers the parts of a micrometer, the main types, reading examples and the rules for correct use.
Parts of a micrometer

- Frame: U-shaped, so the part fits between the measuring faces.
- Heat insulation plate: plastic cover where the frame is held; it reduces expansion from hand heat.
- Anvil: the hardened and ground fixed measuring face.
- Spindle: the moving measuring face that advances as the thimble turns.
- Sleeve: carries the millimetre scale. One side of the reference line shows whole millimetres, the other side half millimetres.
- Thimble: its circumference is divided into 50 equal parts.
- Ratchet stop: limits the measuring force and slips when the part is gripped, so every measurement uses the same force.
- Spindle lock: locks the reading. Do not turn the thimble while it is locked.
Micrometers are usually made in 25 mm ranges: 0–25, 25–50, 50–75 mm and so on. For a 25.1 mm size, for example, choose a 25–50 mm micrometer.
Micrometer types

By reading system micrometers are vernier, dial or digital; by application they are outside, inside, depth, gear tooth and screw thread micrometers.
With special measuring faces a micrometer can also measure non-standard geometry: diameters in narrow grooves, tube wall thickness, gear tooth thickness and the diameter of 3- or 5-flute cutting tools.
How do you read a micrometer? (0.01 mm)
The spindle and nut of a metric micrometer have a 0.5 mm pitch: one turn of the thimble advances the spindle 0.5 mm. The thimble is divided into 50 equal parts, so each thimble line is 0.5 / 50 = 0.01 mm.

- Read the whole and half millimetre value the thimble edge has passed on the sleeve.
- Read the thimble line that lines up with the sleeve reference line and multiply by 0.01.
- Add the two values.

- The thimble has passed 5.50 mm on the sleeve (the half-millimetre line after 5 mm is also visible).
- The thimble line on the reference line is 35: 35 × 0.01 = 0.35 mm.
- Reading: 5.50 + 0.35 = 5.85 mm.
The most common reading mistake is missing the exposed half-millimetre line, which makes the reading 0.5 mm too small.
Reading an inside micrometer

An inside micrometer works on the same principle as an outside micrometer. The difference is that the sleeve scale runs the other way (right to left), so check carefully which millimetre line has been passed.

- Because the scale is reversed and the 22 mm line is visible, the sleeve value is 21.50 mm.
- The coinciding thimble line is 25: 25 × 0.01 = 0.25 mm.
- Reading: 21.50 + 0.25 = 21.75 mm.
Reading a 0.001 mm vernier micrometer

The thimble still has 50 divisions; in addition, the sleeve carries a vernier that divides 9 thimble divisions into 10 equal parts. The resolution becomes 0.01 / 10 = 0.001 mm. Reading takes four steps:
- Read the whole and half millimetres on the sleeve.
- Read the thimble division (0.01 mm).
- Find the sleeve vernier line that lines up with a thimble line (0.001 mm).
- Add the three values.

- Sleeve value: 18.000 mm.
- Thimble line 0 is on the reference line: 0.000 mm.
- The vernier line that lines up with a thimble line is 3: 3 × 0.001 = 0.003 mm.
- Reading: 18.000 + 0.000 + 0.003 = 18.003 mm.
Digital micrometer

Mechanically a digital micrometer is the same as a vernier micrometer; the reading appears on a battery-powered display. It usually has three buttons: zero, absolute/incremental (ABS/INC) and hold. Some models can send readings to a computer. Models that also have sleeve and thimble graduations can still be read mechanically when the battery runs out.
Thread micrometer and thread measurement

A thread micrometer has a conical tip on one side and a V-shaped anvil on the other; the tips sit in the thread form and measure the pitch diameter. The root diameter is measured with a point micrometer.

The measured values are compared with the thread standard. Thread pitch is checked with a screw pitch gauge: gauge types.
Rules for measuring correctly with a micrometer
- Right range: the size must be within the micrometer’s range.
- Temperature: let the micrometer and the part settle in the same environment. Hold the micrometer by its insulated part.
- Viewing angle: look straight at the thimble and sleeve lines.
- Cleanliness and zero: clean the measuring faces with lint-free paper and check zero before measuring.
- Measuring force: bring the spindle close using the knurled thimble and make the final contact with the ratchet. Never force the thimble.
- Mounting: if the micrometer is clamped in a stand, clamp it by the middle of the frame and do not overtighten.

Micrometer accuracy check and zero setting

Accuracy check: measure the setting standard supplied with the micrometer or a gauge block. The difference between the known size of the standard and the reading is the micrometer’s error.

Zero setting: overtightening the thimble, impacts, dropping, pulling it off the part while locked or temperature changes can shift the zero. The zero is corrected by turning the sleeve with the special spanner supplied with the micrometer. Parallelism and flatness of the measuring faces are checked with an optical flat: each interference fringe seen in white light corresponds to about 0.32 µm of height difference. These checks are usually done by the quality department or a calibration laboratory.
Care and storage
- In daily use, clean dust and dirt from around the spindle and from the measuring faces, and wipe off fingerprints with a dry cloth. Sweat and fingerprints cause rust over time.
- If it will not be used for a long time, wipe it with a cloth soaked in anti-corrosion oil.
- Store it in its case, away from direct sunlight, humidity and dust.
- Leave a 0.1 to 1 mm gap between the measuring faces in storage and do not leave the spindle locked.
- A micrometer that has been dropped or knocked must be checked before further use.
For a comparison with calipers and choosing the right instrument: measuring instruments guide. Caliper reading examples: vernier caliper types and reading.
Disclaimer
The information on this page is for general training purposes. Use and care requirements for measuring instruments vary by manufacturer and model; your instrument’s manual and your company’s quality procedures always take priority. An instrument that is out of calibration or damaged gives wrong results. Mentor CNC cannot be held responsible for damage, scrap or injury arising from the use of this information.