A dial indicator is a measuring instrument that shows deviation from a reference rather than an absolute size. It is used every day to check runout, parallelism and flatness and to align vises and parts on CNC machines. Most read 0.01 mm; fine models read 0.001 mm.
Parts of a dial indicator

- Dial and main pointer: on a 0.01 mm indicator the dial has 100 divisions and one full turn of the pointer is 1 mm.
- Revolution counter (small pointer): shows how many turns the main pointer has made, i.e. how many millimetres of travel.
- Rotating bezel: turns the dial so the pointer can be zeroed in any position; it is locked with a screw.
- Tolerance markers: mark the lower and upper limits on the edge of the dial; in batch checking you only look whether the pointer stays between them.
- Stem: where the indicator is clamped to a stand.
- Plunger and contact point: the moving part that touches the workpiece.
The difference from a dial caliper is that the pointer can be zeroed anywhere and that it shows the amount of deviation rather than a distance.
Indicator stands

Magnetic stand: the magnetic base, switched with a lever, holds onto the machine table, the vise or the lathe carriage. The articulated arms let you position the indicator at any angle. This is the most common setup on CNC machines.

Dial test indicator (lever type): the contact point is on a lever arm. It reaches into tight spaces, so it is preferred for bore runout, slot faces and alignment work. It can also be used on a surface plate with a heavy-base stand.
How do you use a dial indicator correctly?

- Clamp the indicator rigidly to the stand; the shorter the arms, the less deflection.
- Bring the contact point square to the surface. On a lever-type indicator the lever should be as parallel to the surface as possible.
- Preload the point slightly so the pointer turns a little. This lets you see deviation in both the plus and the minus direction.
- Turn the bezel to bring the pointer to zero and lock it.
- Move the part or the indicator and read the largest and smallest pointer values.
Contact angle (cosine) error: if the lever of a dial test indicator is at an angle to the surface, the reading is larger than the real movement. The real value is approximately the reading × cos θ. For example, with 0.200 mm on the dial the real movement is about 0.197 mm at θ = 10°, 0.188 mm at θ = 20° and 0.173 mm at θ = 30°. The error grows quickly as the angle increases.
How do you measure runout with a dial indicator?

Runout shows how much a surface “wobbles” when the part turns about its own axis.
- Place the part on V-blocks, between centres or in the lathe chuck.
- Touch the indicator point square to the surface, preload it and zero it.
- Turn the part slowly through one full revolution.
- Note the largest and smallest pointer values.
- Runout (total indicator reading, TIR) = largest − smallest.
Example: with a smallest reading of −0.02 mm and a largest of +0.03 mm, runout is 0.03 − (−0.02) = 0.05 mm.
Where is a dial indicator used on a CNC machine?
- Aligning a vise: the indicator is mounted on the spindle or head and swept along the fixed jaw in X; the vise is tapped round until the pointer stays still.
- Aligning a part: the reference edge of the part is swept the same way to make it parallel to the axis.
- Chuck runout on a lathe: after clamping, diameter and face runout are checked; this matters most with soft jaws and second operations.
- Centring on a bore: a dial test indicator rotated in the spindle finds the centre of a bore or shaft.
For an overview of measurement and tolerances on the lathe: CNC Lathe Training Lesson 9. For the other instruments: measuring instruments guide.
Common mistakes
- Zeroing without preload, so the pointer cannot show deviation in the minus direction.
- Measuring with long, loose arms; deflection is added to the reading.
- Holding the lever of a dial test indicator square to the surface (contact angle error).
- Letting the point hit the part; the internal mechanism is damaged.
Disclaimer
The information on this page is for general training purposes. Use and care requirements for measuring instruments vary by manufacturer and model; your instrument’s manual and your company’s quality procedures always take priority. An instrument that is out of calibration or damaged gives wrong results. Mentor CNC cannot be held responsible for damage, scrap or injury arising from the use of this information.